The |
HES-AIR-i-36-A-N-4 |
Advantages |
Power supply |
V-F-Hz |
230-1-50 |
Maximum power consumption |
Tue |
2200 |
Maximum current consumption |
A |
26,5 |
Cooling |
Performance |
Tue |
10880 |
Performance |
BTU/hr |
34163 |
Power consumption |
Tue |
2200 |
Current consumption |
A |
21 |
EER |
W/W |
2,4 |
Heating |
Performance |
Tue |
13000 |
Performance |
BTU/hr |
36363 |
Power consumption |
Tue |
2200 |
Current consumption |
A |
26 |
COP |
W/W |
2,99 |
Air Volume (High/Middle/Low) |
m3/h |
1900/1600/1400 |
External Static Pressure (ESP) |
Nominal value |
Pa |
37 |
Range |
Pa |
0/160 |
Indoor unit noise level (High/Medium/Low) |
dB(A) |
44/41/39 |
Design pressure (High/Low) |
MPa |
4.1/1.6 |
Drain pipe diameter |
mm |
26 |
The controller |
Remote control |
Compressor |
The |
TNB306FPGMT |
Type |
Rotary |
Brand |
Mitsubishi Electric |
Outdoor unit noise level |
dB(A) |
57 |
Outdoor unit |
Dimensions (WxDxH) |
mm |
800×348×715 |
Packaging (WxDxH) |
mm |
1050×500×890 |
Net/gross weight |
kg |
72.5/77 |
Refrigerant |
Type |
|
R410A |
Refueling volume |
kg |
2,5 |
Refrigerant pipes |
Liquid/ Gas |
mm (inch) |
Ø9.52/Ø12.7(3/8‘/1/2’) |
Maximum length |
m |
65 |
Max. height difference |
m |
30 |
Temperature |
Cooling |
°C |
-5 +43 |
Heating |
°C |
-15 +24 |